Abstract
A study has been carried out to further the understanding of the extrusion process and its impact upon the quality of Blow/Fill/Seal product. Controlled challenges to the extrusion system, comprising low-density polyethylene granulate contaminated with characterized levels of Bacillus atrophaeus (ATCC 9372) endospores and Escherichia coli 055:B5 bacterial endotoxin, have been conducted. Batches of spore contaminated polymer, at challenge levels varying from 103 to 106 spores g−1 polymer with derived D160 values ranging from 1.22 to 2.07 minutes, and endotoxin contaminated polymer, at challenge levels varying from 102 to 104 EU g−1 polymer, were processed through a Blow/Fill/Seal machine employing Tryptone Soya Broth and Water for Injection as the fill mediums, respectively. Relationships have been established between the levels of challenge for each of spores and endotoxin and the extent of product contamination. The relationships allow for prediction of microbiological and pyrogenic quality based upon the microbiological and pyrogenic attributes of unprocessed polymeric granulate and for rationalized choices of polymeric granulate acceptance limits. It is stressed that the findings apply only to the particular Blow/Fill/Seal machine and to the specific conditions of machine operation.
- B/F/S
- Blow/Fill/Seal
- Extruder
- Polymer extrusion
- Spore challenge
- Endotoxin challenge
- Microbiological quality
- Pyrogenic quality
Footnotes
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.