Abstract
The purpose of this study is to assess the impact of real refractive indices, using different itraconazole suspensions, on the associated particle size distributions. Instrumental particle size measurement remains the practical option for determining the particle size distribution of a suspension. In this study, the suspension particle size distribution was measured by static light scattering, which requires knowledge of both the real and imaginary components of the complete refractive index. The real refractive indices of micronized itraconazole raw material, as well as vacuum-dried itraconazole suspension samples obtained from different formulations, polymorphs, manufacturing methods and particle size distributions, were determined using the Becke line method. Identical samples were analyzed by two contract laboratories in order to assess consistency. For the static light scattering equipment used in this study, the complete relative refractive index (RRI = nparticle/ndispersant − ik) input required for software calculation is denoted by a refractive index kernel (RRI input) comprising a relative real component and an imaginary component. The reported real refractive indices for the itraconazole raw material as well as vacuum dried itraconazole suspension samples were different, ranging from 1.608 to 1.65 (selected kernel range of 120A010I to 124A010I). The imaginary component of itraconazole suspension was determined in a previous study to be 010I. The average real refractive index was calculated to be 1.62 (122A010I). The particle size distributions obtained using 120A010I and 124A010I were in good agreement with one generated using 122A010I. Therefore, itraconazole suspensions that were produced using different manufacturing methods/formulations or exhibited different particle size distributions/polymorphic forms may use 122A010I in determining particle size distribution. The particle size distributions determined using RRI input outside the range of 120A010I to 124A010I may not be reliable. However, it is recommended that similar investigations be conducted for other drug suspensions on a case-by-case basis.
- Refractive index
- Complete refractive index
- Itraconazole
- Suspension
- Particle size determination
- Static light scattering
Footnotes
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.