Research ArticleTECHNOLOGY/APPLICATION
Vacuum Decay Container/Closure Integrity Testing Technology. Part 2. Comparison to Dye Ingress Tests
Heinz Wolf, Tony Stauffer, Shu-Chen Y. Chen, Yoojin Lee, Ronald Forster, Miron Ludzinski, Madhav Kamat, Brian Mulhall and Dana Morton Guazzo
PDA Journal of Pharmaceutical Science and Technology September 2009, 63 (5) 489-498;
Heinz Wolf
Tony Stauffer
Shu-Chen Y. Chen
Yoojin Lee
Ronald Forster
Miron Ludzinski
Madhav Kamat
Brian Mulhall
Dana Morton Guazzo

References
- 1.↵
- Wolf H.,
- Stauffer T.,
- Chen S-C. Y.,
- Lee Y.,
- Forster R.,
- Ludzinski M.,
- Kamat M.,
- Godorov P.,
- Guazzo D.
- 2.↵
ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method; ASTM International: West Conshohocken, PA, 2009.
- 3.↵
〈381〉 Elastomeric Closures for Injection. United States Pharmacopeia 31; United States Pharmacopeial Convention, Inc.: Rockville, MD, 2007, First Supplement.
- 4.↵
European Pharmacopoeia 6.0, 3.2.9 Rubber Closures for Containers for Aqueous Parenteral Preparations, for Powders and for Freeze-dried Powders, European Directorate for the Quality of Medicines and Healthcare: Strasbourg, France.
- 5.↵
ISO 8362-5 Injection Containers for Injectables and Accessories—Part 5: Freeze drying closures for injection vials, Annex C Test Method for closure/container integrity and self-sealing, International Organization for Standardization: Geneva, Switzerland.
In This Issue
PDA Journal of Pharmaceutical Science and Technology
Vol. 63, Issue 5
September/October 2009
Vacuum Decay Container/Closure Integrity Testing Technology. Part 2. Comparison to Dye Ingress Tests
Heinz Wolf, Tony Stauffer, Shu-Chen Y. Chen, Yoojin Lee, Ronald Forster, Miron Ludzinski, Madhav Kamat, Brian Mulhall, Dana Morton Guazzo
PDA Journal of Pharmaceutical Science and Technology Sep 2009, 63 (5) 489-498;
Vacuum Decay Container/Closure Integrity Testing Technology. Part 2. Comparison to Dye Ingress Tests
Heinz Wolf, Tony Stauffer, Shu-Chen Y. Chen, Yoojin Lee, Ronald Forster, Miron Ludzinski, Madhav Kamat, Brian Mulhall, Dana Morton Guazzo
PDA Journal of Pharmaceutical Science and Technology Sep 2009, 63 (5) 489-498;
Jump to section
Related Articles
- No related articles found.
Cited By...
- Comparing Container Closure Integrity Test Methods--Performance of Headspace Carbon Dioxide Analysis versus Helium Leakage Using Positive Controls
- Container closure integrity testing and process validation of closed system transfer devices for aseptic reconstitution of drug vials connected to fluid bags
- Comparing Physical Container Closure Integrity Test Methods and Artificial Leak Methodologies
- Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes
- Non-Destructive Vacuum Decay Method for Pre-Filled Syringe Closure Integrity Testing Compared with Dye Ingress Testing and High-Voltage Leak Detection
- Development of a Nondestructive Leak Testing Method Utilizing the Head Space Analyzer for Ampoule Products Containing Ethanol-Based Solutions
- Vacuum Decay Container Closure Integrity Leak Test Method Development and Validation for a Lyophilized Product-Package System