Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleRESEARCH

Studies on Viral Disinfection: An Evaluation of Moist Heat Disinfection for HBV by Using A0 Concept Defined in ISO 15883-Washer-Disinfectors

Yushi Uetera, Kunio Kawamura, Hiroyoshi Kobayashi, Yuhei Saito, Hiroshi Yasuhara and Ryoichi Saito
PDA Journal of Pharmaceutical Science and Technology July 2010, 64 (4) 327-336;
Yushi Uetera
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kunio Kawamura
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hiroyoshi Kobayashi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yuhei Saito
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hiroshi Yasuhara
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ryoichi Saito
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

International Organization for Standardization (ISO) 15883 for washer-disinfectors has introduced the A0 concept to allow comparison of the lethality of moist heat processes. The A0 value is the equivalent disinfection time in seconds at 80 °C calculated on the basis of microbial killing kinetics when the disinfection temperature is over 65 °C. Hepatitis B virus (HBV), transmissible only to humans and chimpanzees, is an important heat-resistant, blood-borne pathogen. Therefore, it is mandatory to disinfect HBV thoroughly in the washer-disinfectors employed for surgical instruments. Additionally, it has become extremely difficult to use chimpanzees as experimental models or to perform human volunteer studies. Therefore, it is considered worthwhile to re-evaluate the reported data on the moist heat disinfection of HBV using the A0 value. In the voluntary active immunization to humans in 1973, HBV serum (infectivity titer: 106.5 CID50/mL) underwent moist heat disinfection at 98 °C for 1 min in a flask over an electric burner (conservatively estimated A0 value: 3786). Then, 0.1 mL was inoculated to each of 29 volunteers. No one revealed evidence of infection clinically or in the laboratory tests available at the time. In 1979, a more sensitive test appeared and revealed three sub-clinically infected volunteers. In the 1980s, there were two chimpanzee experimental models using HBV serum (infectivity titer: 105 CID50/mL). In one model, the serum underwent moist heat disinfection at 98 °C for 2 min in a thermostat bath (conservatively estimated A0 value: 7571). One milliliter was inoculated to each of two chimpanzees, and both of them revealed no evidence of infection. In another model, the serum underwent moist heat disinfection using two conditions in a thermostat bath, respectively: at 103 °C for 90 s (A0 value: 24865) and at 65 °C for 10 h (A0 value: 1138). Ten milliliters of each sample were mixed. Then, the mixture was inoculated to each of two chimpanzees. Both of them revealed no evidence of infection. In the human volunteer study, the serum infectivity titer was more than 30 times (101.5 times) higher than that used in the two chimpanzee experimental models. Moreover, the serum was heated in the flask over an electric burner, which is considered less reliable than the thermostat baths to realize uniform heat distribution. It is assumed that these factors were predisposed to the result that a conservatively estimated A0 value of 3786 failed to inactivate the HBV serum of 106.5 CID50/mL. In the two chimpanzee models, it was suggested that A0 value not less than 1138 was able to inactivate the HBV serum of 105 CID50/mL.

  • Thermal disinfection
  • Moist heat disinfection
  • A0 value
  • A0 concept
  • Washer-disinfector
  • Hepatitis B virus (HBV)
  • © PDA, Inc. 2010
View Full Text

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 64 (4)
PDA Journal of Pharmaceutical Science and Technology
Vol. 64, Issue 4
July/August 2010
  • Table of Contents
  • Index by Author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Studies on Viral Disinfection: An Evaluation of Moist Heat Disinfection for HBV by Using A0 Concept Defined in ISO 15883-Washer-Disinfectors
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
4 + 11 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Studies on Viral Disinfection: An Evaluation of Moist Heat Disinfection for HBV by Using A0 Concept Defined in ISO 15883-Washer-Disinfectors
Yushi Uetera, Kunio Kawamura, Hiroyoshi Kobayashi, Yuhei Saito, Hiroshi Yasuhara, Ryoichi Saito
PDA Journal of Pharmaceutical Science and Technology Jul 2010, 64 (4) 327-336;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Studies on Viral Disinfection: An Evaluation of Moist Heat Disinfection for HBV by Using A0 Concept Defined in ISO 15883-Washer-Disinfectors
Yushi Uetera, Kunio Kawamura, Hiroyoshi Kobayashi, Yuhei Saito, Hiroshi Yasuhara, Ryoichi Saito
PDA Journal of Pharmaceutical Science and Technology Jul 2010, 64 (4) 327-336;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • References
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • The Role of Heat-Tolerant Endotoxin-Retentive Ultrafilters (UFs) for the Remediation of Reverse Osmosis (RO) Plants Employed for Surgical Hand Antisepsis Using Periodic Thermal Disinfection--A Ten Year Longitudinal Experience Study in the Operating Theater
  • Google Scholar

More in this TOC Section

  • A Holistic Approach for Filling Volume Variability Evaluation and Control with Statistical Tool
  • A Proof-of-Concept Study on a Universal Standard Kit to Evaluate the Risks of Inspectors for Their Foundational Ability of Visual Inspection of Injectable Drug Products
  • Quantitative and Qualitative Evaluation of Microorganism Profile Identified in Bioburden Analysis in a Biopharmaceutical Facility in Brazil: Criteria for Classification and Management of Results
Show more Research

Similar Articles

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire