Abstract
CONFERENCE PROCEEDING Proceedings of the PDA/FDA Adventitious Viruses in Biologics: Detection and Mitigation Strategies Workshop in Bethesda, MD, USA; December 1–3, 2010
Guest Editors: Arifa Khan (Bethesda, MD), Patricia Hughes (Bethesda, MD) and Michael Wiebe (San Francisco, CA)
Viral contamination of biotech product facilities is a potentially devastating manufacturing risk and, unfortunately, is more common than is generally reported or previously appreciated. Although viral contaminants of biotech products are thought to originate principally from biological raw materials, all potential process risks merit evaluation. Limitations to existing methods for virus detection are becoming evident as emerging viruses have contaminated facilities and disrupted supplies of critical products. New technologies, such as broad-based polymerase chain reaction screens for multiple virus types, are increasingly becoming available to detect adventitious viral contamination and thus, mitigate risks to biotech products and processes. Further, the industry embrace of quality risk management that promotes improvements in testing stratagems, enhanced viral inactivation methods for raw materials, implementation and standardization of robust viral clearance procedures, and efforts to learn from both epidemiologic screening of raw material sources and from the experience of other manufacturers with regard to this problem will serve to enhance the safety of biotech products available to patients. Based on this evolving landscape, we propose a set of principles for manufacturers of biotech products: Pillars of Risk Mitigation for Viral Contamination of Biotech Products.
- © PDA, Inc. 2011
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.