Abstract
The BacT/ALERT® 3D system was validated to determine the sterility of different types of biopharmaceutical samples such as water for injection, unprocessed bulk, and finished bulk. The installation, operation, and performance qualification were completed and verified under good manufacturing practices. During the installation and operation validation stages, the functionality and security of the system and software were completed and verified. For the performance qualification, 11 microorganisms were evaluated, six compendial (Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus subtilis, Candida albicans, Aspergillus niger, Clostridium sporogenes), one representing the number one microbial species in sterile product recalls (Burkholderia cepacia), and four environmental isolates (Kocuria rhizophila, Staphylococcus haemolyticus, Methylobacterium radiotolerans, and Penicillium spp.). Nine of the microorganisms were spiked into three different types of biopharmaceutical samples by three different analysts on different days to ascertain the equivalence, ruggedness, sensitivity, time of detection, and repeatability. In all samples, the BacT/ALERT® exhibited equivalent or better detection than the standard test. With the exception of M. radiotolerans, all 11 microorganisms were detected within 2.5 days using the BacT/ALERT® system and the standard test. The detection times for M. radiotolerans in the three sample types averaged 5.77 days. The minimum detectable level of cells for all the microorganisms tested was found to be within 1 to 2 CFU. The system optimized sterility testing by the simultaneous on-line, non-destructive incubation and detection of microbial growth.
- © PDA, Inc. 2012
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.