Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleTechnology/Application

Characterization of the Initial Level and Migration of Silicone Oil Lubricant in Empty Prefilled Syringes for Biologics Using Infrared Spectroscopy

Jared S. Bee, Vadim V. Frey, Urooj Javed, Jonathan Chung, Marta L. Corcoran, Paul S. Roussel, Stephan O. Krause, Patricia W. Cash, Steven M. Bishop and Mariana N. Dimitrova
PDA Journal of Pharmaceutical Science and Technology September 2014, 68 (5) 494-503; DOI: https://doi.org/10.5731/pdajpst.2014.00991
Jared S. Bee
1Formulation Sciences, MedImmune, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: jaredsbee@gmail.com
Vadim V. Frey
2Analytical Biotechnology, MedImmune, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Urooj Javed
2Analytical Biotechnology, MedImmune, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jonathan Chung
3Drug Delivery & Devices, MedImmune, Gaithersburg, MD; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marta L. Corcoran
2Analytical Biotechnology, MedImmune, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paul S. Roussel
3Drug Delivery & Devices, MedImmune, Gaithersburg, MD; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephan O. Krause
2Analytical Biotechnology, MedImmune, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patricia W. Cash
2Analytical Biotechnology, MedImmune, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Steven M. Bishop
1Formulation Sciences, MedImmune, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mariana N. Dimitrova
4Protein Pharmaceutical Development, Biogen Idec Inc., Boston, MA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 68 no. 5 494-503
DOI 
https://doi.org/10.5731/pdajpst.2014.00991
PubMed 
25336420

Published By 
Parenteral Drug Association (PDA)
Print ISSN 
1079-7440
Online ISSN 
1948-2124
History 
  • Published online October 21, 2014.

Copyright & Usage 
© PDA, Inc. 2014

Author Information

  1. Jared S. Bee1,*,
  2. Vadim V. Frey2,
  3. Urooj Javed2,
  4. Jonathan Chung3,
  5. Marta L. Corcoran2,
  6. Paul S. Roussel3,
  7. Stephan O. Krause2,
  8. Patricia W. Cash2,
  9. Steven M. Bishop1 and
  10. Mariana N. Dimitrova4
  1. 1Formulation Sciences, MedImmune, Gaithersburg, MD;
  2. 2Analytical Biotechnology, MedImmune, Gaithersburg, MD;
  3. 3Drug Delivery & Devices, MedImmune, Gaithersburg, MD; and
  4. 4Protein Pharmaceutical Development, Biogen Idec Inc., Boston, MA
  1. ↵*Corresponding Author: One Medimmune Way, Gaithersburg, MD 20878. (301)-398-5912; e-mail: jaredsbee{at}gmail.com
View Full Text

Cited By...

  • 8 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Silicone Migration From Baked-on Silicone Layers. Particle Characterization in Placebo and Protein Solutions
    Stefanie Funke, Julia Matilainen, Heiko Nalenz, Karoline Bechtold-Peters, Hanns-Christian Mahler, Wolfgang Friess
    Journal of Pharmaceutical Sciences 2016 105 12
  • Impact of Surfactants on the Functionality of Prefilled Syringes
    Tingting Wang, Coralie A. Richard, Xia Dong, Galen Huaiqiu Shi
    Journal of Pharmaceutical Sciences 2020 109 11
  • Optimization of the bake-on siliconization of cartridges. Part I: Optimization of the spray-on parameters
    Stefanie Funke, Julia Matilainen, Heiko Nalenz, Karoline Bechtold-Peters, Hanns-Christian Mahler, Wolfgang Friess
    European Journal of Pharmaceutics and Biopharmaceutics 2016 104
  • Optimization of the bake-on siliconization of cartridges. Part II: Investigations into burn-in time and temperature
    Stefanie Funke, Julia Matilainen, Heiko Nalenz, Karoline Bechtold-Peters, Hanns-Christian Mahler, Florian Vetter, Christoph Müller, Franz Bracher, Wolfgang Friess
    European Journal of Pharmaceutics and Biopharmaceutics 2016 105
  • Prefilled dual chamber devices (DCDs) – Promising high-quality and convenient drug delivery system
    Rahul G. Ingle, Wei-Jie Fang
    International Journal of Pharmaceutics 2021 597
  • A framework to optimize spring-driven autoinjectors
    Xiaoxu Zhong, Ilias Bilionis, Arezoo M. Ardekani
    International Journal of Pharmaceutics 2022 617
  • Analysis of Silicone Oil in Prefilled Syringes and Biopharmaceutical Drug Products Using High-Performance Liquid Chromatography
    Jian Liu, Mike Ronk, Kiyoshi Fujimori, Hans Lee, Yasser Nashed-Samuel
    AAPS PharmSciTech 2021 22 2
  • High-Throughput Fluorometric Assay For Quantifying Polysorbate In Biopharmaceutical Products Using Micelle Activated Fluorescence Probe N-Phenyl-1-Naphthylamine
    Ximeng Y. Dow, Qi Gao, John L. Sperduto, Xiaona Wen, Christopher Thai, Lei Zhang, Mark A. McCoy
    Pharmaceutical Research 2024 41 7
PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 68 (5)
PDA Journal of Pharmaceutical Science and Technology
Vol. 68, Issue 5
September/October 2014
  • Table of Contents
  • Index by Author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Characterization of the Initial Level and Migration of Silicone Oil Lubricant in Empty Prefilled Syringes for Biologics Using Infrared Spectroscopy
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
2 + 0 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Characterization of the Initial Level and Migration of Silicone Oil Lubricant in Empty Prefilled Syringes for Biologics Using Infrared Spectroscopy
Jared S. Bee, Vadim V. Frey, Urooj Javed, Jonathan Chung, Marta L. Corcoran, Paul S. Roussel, Stephan O. Krause, Patricia W. Cash, Steven M. Bishop, Mariana N. Dimitrova
PDA Journal of Pharmaceutical Science and Technology Sep 2014, 68 (5) 494-503; DOI: 10.5731/pdajpst.2014.00991

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Characterization of the Initial Level and Migration of Silicone Oil Lubricant in Empty Prefilled Syringes for Biologics Using Infrared Spectroscopy
Jared S. Bee, Vadim V. Frey, Urooj Javed, Jonathan Chung, Marta L. Corcoran, Paul S. Roussel, Stephan O. Krause, Patricia W. Cash, Steven M. Bishop, Mariana N. Dimitrova
PDA Journal of Pharmaceutical Science and Technology Sep 2014, 68 (5) 494-503; DOI: 10.5731/pdajpst.2014.00991
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Experimental
    • Results and Discussion
    • Conflict of Interest Declaration
    • References
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Assessment of Functional and Physical Performances of Pre-filled Syringes in Deep Cold Storage Conditions
  • Evaluation of a Novel Prefilled Syringe Concept for Ophthalmic Applications: A Formative Human Factors Study
  • Method Comparison Study--One Step Forward toward Robust Silicone Layer Thickness Measurements
  • Physicochemical Excipient-Container Interactions in Prefilled Syringes and Their Impact on Syringe Functionality
  • Drug Formulation Impact on Prefilled Syringe Functionality and Autoinjector Performance
  • Methods To Determine the Silicone Oil Layer Thickness in Sprayed-On Siliconized Syringes
  • Impact of Drug Formulation Variables on Silicone Oil Structure and Functionality of Prefilled Syringe System
  • Google Scholar

More in this TOC Section

  • Mechanical Container Closure Integrity Test: A Method for Cartridge Systems
  • A Container Closure Integrity Test Method for Vials Stored at Cryogenic Conditions Using Headspace Oxygen Analysis
  • Best Practices for Microbial Challenge In-Use Studies to Evaluate the Microbial Growth Potential of Parenteral Biological Products; Industry and Regulatory Considerations
Show more Technology/Application

Similar Articles

Keywords

  • Silicone oil
  • prefilled syringe
  • Device
  • Infrared spectroscopy

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire