Abstract
For biotherapeutics and vaccines, potency is measured in a bioassay that compares the concentration-response curves of a new batch to that of a reference standard. Acceptable accuracy and precision of potency measurement is critical to the manufacturing of these products. These characteristics of a bioassay are typically assessed in a procedure that is carried out with samples spanning the acceptable range for the product. During early development, however, a full validation study such as that which is carried out in late development can be costly as it relates to the likelihood of eventual program success. For these reasons, the laboratory may look for alternative ways to ensure the validity of the bioassay across a range that will support product development. One such alternative combines information from a reduced procedure using only reference standard and 100% relative potency concentration-response data sets, together with computer simulation, to estimate missing relative potency values across the desired range. Fits to the reduced dataset provide estimates of bioassay model parameters such as those for an S-shaped potency assay that follows a four-parameter logistic relationship, along with estimates of their variance-covariance structure and independent experimental unit (e.g., well-to-well or animal-to-animal) errors. Using Bayesian Markov Chain Monte Carlo modeling, the predictive distribution of the concentration-response data for the desired levels of relative potency is generated. Results from use of the reduced procedure are compared to results calculated from a full dataset in Monte Carlo simulation and in a motivating example.
LAY ABSTRACT: For biotherapeutics and vaccines, potency is measured in a bioassay that compares the concentration-response curves of a new batch to that of a reference standard. Acceptable accuracy and precision of potency measurement is critical to the manufacturing of these products. These characteristics of a bioassay are typically assessed in a procedure that is carried out with samples spanning the acceptable range for the product. During early development, however, a full validation study such as that which is carried out in late development can be costly as it relates to the likelihood of eventual program success. For these reasons, the laboratory may look for alternative ways to ensure the validity of the bioassay across a range that will support product development. One such alternative combines information from a reduced procedure using only reference standard and 100% relative potency concentration-response data sets, together with computer simulation, to estimate missing relative potency values across the desired range. Bayesian Markov Chain Monte Carlo modeling is used to generate the distributions of the missing potency levels. Results from use of the reduced procedure are compared to results calculated from a full dataset in Monte Carlo simulation and in a motivating example.
- © PDA, Inc. 2018
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.