Abstract
Recently, the use of filters has come into light for sanitizing water plants. This study investigated the role of heat-tolerant ultrafilters (UFs) for the remediation of reverse osmosis (RO) plants using periodic thermal disinfection. Two completely identical RO plants (RO plants A and B) were installed in 2006 for surgical hand antisepsis in the operating theater. RO water was stored in the 300 L storage tank and recirculated in the 190 meter-long loop delivering water to 12 faucets in each RO plant. Periodic thermal disinfection came into practice periodically when a UF module was retrofitted to the recirculation loop of each RO plant in 2010. Endotoxin was monitored closely before and after thermal disinfection. Before UF modules were retrofitted, endotoxin increased to a maximum of 0.301 EU/mL in RO plant A and 1.446 EU/mL in RO plant B after thermal disinfection, respectively. Since a UF module was retrofitted to each RO plant in 2010, endotoxin has been continuously below 0.025 EU/mL in RO plant A and exceeded this level five times in RO plant B. On one occasion, endotoxin increased in all samples collected simultaneously after solenoid valves were replaced in the recirculation loop near the air conditioner outlet. At this time, the inside of the pipework was exposed to the ventilation airflow. After the valves were replaced again, this time with the workplace isolated using a curing sheet, endotoxin decreased. On the other occasions, endotoxin increased only in one sample and decreased after thermal disinfection. Annually replaced UF modules were examined twice for estimating the amounts of immobilized endotoxin. The estimated amounts decreased in 2013 by the order of 10–3 in comparison with those in 2011 in both RO plants. The present study suggested that UFs acted synergistically with periodic thermal disinfection for the remediation of RO plants.
- Reverse osmosis (RO) plants
- Thermal disinfection
- Hot water sanitization
- A0 (A naught) concept
- Endotoxin
- Heat-tolerant ultrafilters (UFs)
- © PDA, Inc. 2018
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.