Abstract
The terminal sterilization of drugs and devices is the most appropriate means of assuring patient safety in terms of infection prevention. Adoption of terminal sterilization processes requires a supporting and thorough program for control and monitoring of bioburden, especially if a parametric release program of sterilization is desired. Such a control program should necessarily assess and evaluate the associated bioburden (primarily spores), which may resist inactivation and challenge the sterilization cycle. The bioburden resistance can be evaluated by several means and procedures (e.g., the boil test); however, these procedures should be designed and implemented taking into consideration the nature of the spore and spore recovery. This short review describes the application of moist heat resistance for the terminal sterilization of drugs.
LAY ABSTRACT: The terminal sterilization of drugs and devices is the most appropriate means of assuring patient safety in terms of infection prevention. Adoption of terminal sterilization processes requires a supporting and thorough program for control and monitoring of bioburden, especially if a parametric release program of sterilization is desired. This short review describes the application of moist heat resistance for the terminal sterilization of drugs.
- Microbiological tests
- Boil test
- Moist heat sterilization
- Terminal sterilization
- Overkill
- Bioburden
- Biological indicator
- Spores
- Spore inactivation
- Spore germination
- Spore outgrowth
- Bioburden control
- Parametric release
- © PDA, Inc. 2018
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.