Abstract
Understanding the contribution of relevant factors to the analytical variability of the micro-flow imaging (MFI) technique is of prime importance because of the significance of the subvisible particulate data in biopharmaceutical product development. The current study was performed to determine the contribution of several key variables to the variability of the subvisible particle counts (e.g., day-to-day, vial-to-vial, sample-to-sample, and measurement-to-measurement variabilities) using a nested statistical analysis. The variability was measured in the <10 μm, ≥10 μm, ≥25 μm, and ≥50 μm size ranges along with the total particle count and the maximum and the mean particle size. The contribution of the vial to the variability of the subvisible particle counts was found to be greater than those of the other factors evaluated in the current study. The analytical method variability in terms of percent relative standard deviation with respect to the particle count in the <10 μm, ≥10 μm, and ≥25 μm size ranges was found to be 16%, 40%, and 44%, respectively. A thorough understanding of the contribution of key factors to the analytical variability revealed how the corresponding contribution can be minimized, that is, by increasing the number of vials, samples, and measurements. The results of the current study may be leveraged for the optimization of the analytical method or for minimization of the analytical variability with the MFI technique.
- Micro-flow imaging
- Subvisible particles
- Analytical variability
- Factors influencing
- Statistical analysis
- Assay precision
- © PDA, Inc. 2020
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.