Abstract
Steam sterilization is widely used across the healthcare industry and is the most documented and standardized sterilization method. Despite its broad application, there is considerable confusion regarding the different process control considerations and sterilizer designs necessary for its successful use. The methods and equipment used for porous loads (equipment, components, and tools) are established to address air removal and steam penetration as these are critical to process efficacy. Sterilizing processes and equipment for non-porous loads (sealed aqueous containers) seek to minimize variations across the load and minimize the potential for under- or over-processing of portions of the load. These distinctions are not always evident in publications. The United States Pharmacopeia content brought attention to these differences in General Chapter <1229.1> Sterilization by Direct Contact and General Chapter <1229.2> Moist Heat Sterilization of Aqueous Liquids. This publication provides expanded content beyond that found in USP in a side-by-side comparison of the process considerations and equipment design details. It also reviews sterilization practices in laboratory, formulation, and biowaste sterilization applications, which often require the simultaneous sterilization of porous and non-porous items.
- Steam sterilization
- Terminal sterilization
- Porous loads
- Non-porous loads
- Sterilizer design
- United States Pharmacopeia
- © PDA, Inc. 2020
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.