Abstract
As described in USP Chapter <1207>, the deterministic leak test methods using laser-based gas headspace analysis and helium leakage are those with the highest sensitivities. As stated in the chapter, ″no single package leak test or package seal quality test method is applicable to all product-package systems″; therefore, knowing the advantages and disadvantages of both of these techniques, and the extent to which they can be substituted for each other, is valuable. In an effort to begin addressing this issue, a systematic study using these two techniques has been performed. This study used the same well-defined positive controls prepared with microcapillaries for both measurement techniques. For the headspace gas analysis technique, the headspace carbon dioxide content was measured at multiple timepoints during three separate conditioning cycles using either a 0.5, 1.0, or 2.0 bar CO2 overpressure; the observed change in headspace carbon dioxide was then used to determine an ingress rate for each positive control. For the helium leakage technique, the positive controls were measured with a standard helium leak detector with 100% helium atmosphere on the atmospheric pressure side of the artificial defects. The resulting leakage rates from both techniques were compared for ingress into both ISO 2R and ISO 10R vials. The obtained correlation between helium and carbon dioxide leakage rates resulted in a minimum R2 coefficient of 0.98 across all 12 runs. Additionally, both setups met the acceptance criteria for accuracy with their respective calibrated standards.
- Container closure integrity
- USP <1207>
- carbon dioxide
- frequency modulation spectroscopy
- headspace gas analysis
- helium leakage
- Received July 25, 2023.
- Accepted June 11, 2024.
- Copyright © 2024, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.