Skip to main content
  • Main menu
  • User menu
  • Search

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleTECHNOLOGY/APPLICATIONS

Validation of a High Voltage Leak Detector for Use With Pharmaceutical Blow-Fill-Seal Containers—A Practical Approach

F. Möll, D. L. Doyle, M. Haerer and D. Morton Guazzo
PDA Journal of Pharmaceutical Science and Technology September 1998, 52 (5) 215-227;
F. Möll
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D. L. Doyle
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Haerer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D. Morton Guazzo
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Proposed requirements for pharmaceutical package integrity testing outlined in the EU Guide for Sterile Medicinal Products may make it necessary to evaluate and validate alternate ways to perform 100% leak inspection. One such method is high voltage leak detection (HVLD). Even though HVLD has been used for glass ampoules and vials for years, qualification and validation strategies are not well established. In this article, we describe and discuss our practical approach to validation and the protocols used to qualify and validate a high voltage leak detector for use with blow-fill-seal containers. For this work, we used laser drilled pinholes as a model for pinholes produced during manufacturing and defined a “window diagram.” This diagram allowed us to plot the parameters of influence and the settings of the HVLD in an easy to visualize pictorial display. In the validation step, we initially determined the most sensitive standard integrity test for our product and container design from the available choices, the vacuum chamber, dye bath and microbial challenge visual inspection tests. In the next phase of our work, the HVLD was crossed-validated against the most sensitive of these tests, the dye bath visual inspection test. This was accomplished with a large number of containers mixed with deliberately defective ampoules. Our conclusion from this work is that the HVLD is an appropriate and feasible integrity test for 100% inspection of blow-fill-seal containers.

Footnotes

    • Received December 23, 1997.
    • Accepted May 26, 1998.
  • Copyright © Parenteral Drug Association. All rights reserved.
PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology
Vol. 52, Issue 5
September/October 1998
  • Table of Contents
  • Index by Author
Download PDF
Article Alerts
Email Article
Citation Tools
Share
Validation of a High Voltage Leak Detector for Use With Pharmaceutical Blow-Fill-Seal Containers—A Practical Approach
F. Möll, D. L. Doyle, M. Haerer, D. Morton Guazzo
PDA Journal of Pharmaceutical Science and Technology Sep 1998, 52 (5) 215-227;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Container Closure Integrity Testing--Practical Aspects and Approaches in the Pharmaceutical Industry
  • High-Voltage Leak Detection of a Parenteral Proteinaceous Solution Product Packaged in Form-Fill-Seal Plastic Laminate Bags. Part 1. Method Development and Validation
  • Google Scholar

More in this TOC Section

  • Evaluation of Steam Sterilization Processes: Comparing Calculations Using Temperature Data and Biointegrator Reduction Data and Calculation of Theoretical Temperature Difference
  • Optimization of the Drug Solution Preparation Process for a Production-Scale Crossflow Ultrafiltration System
  • Bacterial Adhesion: Considerations Within A Risk-Based Approach To Cleaning Validation
Show more Technology/Applications

Similar Articles

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Validation of a High Voltage Leak Detector for Use With Pharmaceutical Blow-Fill-Seal Containers—A Practical Approach
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
9 + 6 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Validation of a High Voltage Leak Detector for Use With Pharmaceutical Blow-Fill-Seal Containers—A Practical Approach
F. Möll, D. L. Doyle, M. Haerer, D. Morton Guazzo
PDA Journal of Pharmaceutical Science and Technology Sep 1998, 52 (5) 215-227;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.