Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleRESEARCH ARTICLE

The Effect on Syringe Performance of Fluid Storage and Repeated Use: Implications for Syringe Pumps

David F. Capes, Dennis Herring, V. Bruce Sunderland, Dale McMillan and Charles Mcdonald
PDA Journal of Pharmaceutical Science and Technology January 1996, 50 (1) 40-50;
David F. Capes
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dennis Herring
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
V. Bruce Sunderland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dale McMillan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Charles Mcdonald
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Syringe stiction has been reported to cause syringe pump malfunction, hence the effect on syringe performance of syringe use and the formulations used in the syringe were investigated. The force required for syringe plunger motion (at 2.5 mm min–1), when filled with soybean oil emulsion (SBOE) and with water, and the extraction of silicone oil from syringes by these fluids, were measured for Primo®, Talus and Terumo® 10 mL, and Terumo 50 mL syringes. The breakloose, average extrusion and maximum force required to maintain plunger motion increased after storage of SBOE for 7 days in all syringes tested (p < 0.05). The storage of water increased the breakloose force of all syringes, but only increased the maximum force of Talus syringes, and both the average extrusion and maximum forces of Terumo 10 mL syringes. The mechanism for this is most likely swelling of the elastomer of the piston due to sorption of fluid. The force was found to increase logarithmically with repeated syringe use. Electrothermal atomization atomic absorption spectroscopy was used to measure the silicone oil content of syringe extractions. Three extractions were performed: repeated flushing, vigorous washing, and storage for 7 days with occasional agitation. Up to 69.4% of the silicone oil present in the syringes was extracted with both water and SBOE when they were stored or washed. In contrast to water, SBOE also extracted the lubricant when the syringe was filled and flushed immediately. If syringes are refilled, stored filled before use, or used over a prolonged period, particularly with a SBOE formulation, syringe stiction may occur during infusion with a syringe pump.

  • Received November 11, 1994.
  • Accepted July 21, 1995.
  • Copyright © Parenteral Drug Association. All rights reserved.

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology
Vol. 50, Issue 1
January-February 1996
  • Table of Contents
  • Index by Author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Effect on Syringe Performance of Fluid Storage and Repeated Use: Implications for Syringe Pumps
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
6 + 10 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
The Effect on Syringe Performance of Fluid Storage and Repeated Use: Implications for Syringe Pumps
David F. Capes, Dennis Herring, V. Bruce Sunderland, Dale McMillan, Charles Mcdonald
PDA Journal of Pharmaceutical Science and Technology Jan 1996, 50 (1) 40-50;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Effect on Syringe Performance of Fluid Storage and Repeated Use: Implications for Syringe Pumps
David F. Capes, Dennis Herring, V. Bruce Sunderland, Dale McMillan, Charles Mcdonald
PDA Journal of Pharmaceutical Science and Technology Jan 1996, 50 (1) 40-50;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Monitoring of Mannitol Phase Behavior during Freeze-Drying Using Non-Invasive Raman Spectroscopy
  • Long-Term Stabilization of a New Freeze-Dried and Albumin-Free Formulation of Recombinant Human Interferon Alpha 2b
  • A Novel Approach to the Statistical Evaluation of Media Fill Tests by the Difference from No Contamination Data
Show more RESEARCH ARTICLE

Similar Articles

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire