Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleRESEARCH ARTICLE

Measuring the Thermal Resistance of Microorganisms: Selecting an Appropriate Test System, Correcting for Heat-transfer Lags, and Determining Minimum Heating Times

Irving J. Pflug
PDA Journal of Pharmaceutical Science and Technology May 2003, 57 (3) 160-185;
Irving J. Pflug
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Errors that occur in physical systems used to evaluate the heat resistance of microorganisms are discussed: namely, (a) not knowing the test heating-medium temperature accurately, (b) using heating times that are so short that the maximum temperature reached in the test unit is significantly below the test heating-medium temperature, and (c) ignoring significant heat-transfer lags, first in the heating and later in the cooling of the test units.

Procedures and methods that can be used to minimize the effect of potential test-system errors on microbial resistance data are reported. Examples are included regarding the treatment of the different types of errors. Heating and cooling lag-correction values for several commonly-used testing systems, gleaned from the published literature and from the author's experience, are listed.

A method is described and illustrated regarding how we may determine (in advance of carrying out an experiment to gather enumeration or survivor-curve data), the shortest heating time—highest temperature that should be used with a specific test-unit system and microbial DT -value.

Footnotes

  • Copyright © Parenteral Drug Association. All rights reserved.

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology
Vol. 57, Issue 3
May/June 2003
  • Table of Contents
  • Index by Author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Measuring the Thermal Resistance of Microorganisms: Selecting an Appropriate Test System, Correcting for Heat-transfer Lags, and Determining Minimum Heating Times
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
5 + 8 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Measuring the Thermal Resistance of Microorganisms: Selecting an Appropriate Test System, Correcting for Heat-transfer Lags, and Determining Minimum Heating Times
Irving J. Pflug
PDA Journal of Pharmaceutical Science and Technology May 2003, 57 (3) 160-185;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Measuring the Thermal Resistance of Microorganisms: Selecting an Appropriate Test System, Correcting for Heat-transfer Lags, and Determining Minimum Heating Times
Irving J. Pflug
PDA Journal of Pharmaceutical Science and Technology May 2003, 57 (3) 160-185;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Studies on Viral Disinfection: An Evaluation of Moist Heat Disinfection for HBV by Using A0 Concept Defined in ISO 15883-Washer-Disinfectors
  • Google Scholar

More in this TOC Section

  • Monitoring of Mannitol Phase Behavior during Freeze-Drying Using Non-Invasive Raman Spectroscopy
  • Long-Term Stabilization of a New Freeze-Dried and Albumin-Free Formulation of Recombinant Human Interferon Alpha 2b
  • Pharmaceutical Development of an Intravenous Dosage Form of Diacetylmorphine Hydrochloride
Show more RESEARCH ARTICLE

Similar Articles

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire