Skip to main content
  • Main menu
  • User menu
  • Search

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleResearch

A Novel Method for Qualification of a Potency Assay through Partial Computer Simulation

Steven Novick, Perceval Sondag, Tim Schofield and Kenneth Miller
PDA Journal of Pharmaceutical Science and Technology May 2018, 72 (3) 249-263; DOI: https://doi.org/10.5731/pdajpst.2017.008094
Steven Novick
1MedImmune LLC, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: novicks@medimmune.com
Perceval Sondag
2Arlenda Inc., Berwyn, PA; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tim Schofield
3GlaxoSmithKline PLC, Rockville, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kenneth Miller
1MedImmune LLC, Gaithersburg, MD;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

For biotherapeutics and vaccines, potency is measured in a bioassay that compares the concentration-response curves of a new batch to that of a reference standard. Acceptable accuracy and precision of potency measurement is critical to the manufacturing of these products. These characteristics of a bioassay are typically assessed in a procedure that is carried out with samples spanning the acceptable range for the product. During early development, however, a full validation study such as that which is carried out in late development can be costly as it relates to the likelihood of eventual program success. For these reasons, the laboratory may look for alternative ways to ensure the validity of the bioassay across a range that will support product development. One such alternative combines information from a reduced procedure using only reference standard and 100% relative potency concentration-response data sets, together with computer simulation, to estimate missing relative potency values across the desired range. Fits to the reduced dataset provide estimates of bioassay model parameters such as those for an S-shaped potency assay that follows a four-parameter logistic relationship, along with estimates of their variance-covariance structure and independent experimental unit (e.g., well-to-well or animal-to-animal) errors. Using Bayesian Markov Chain Monte Carlo modeling, the predictive distribution of the concentration-response data for the desired levels of relative potency is generated. Results from use of the reduced procedure are compared to results calculated from a full dataset in Monte Carlo simulation and in a motivating example.

LAY ABSTRACT: For biotherapeutics and vaccines, potency is measured in a bioassay that compares the concentration-response curves of a new batch to that of a reference standard. Acceptable accuracy and precision of potency measurement is critical to the manufacturing of these products. These characteristics of a bioassay are typically assessed in a procedure that is carried out with samples spanning the acceptable range for the product. During early development, however, a full validation study such as that which is carried out in late development can be costly as it relates to the likelihood of eventual program success. For these reasons, the laboratory may look for alternative ways to ensure the validity of the bioassay across a range that will support product development. One such alternative combines information from a reduced procedure using only reference standard and 100% relative potency concentration-response data sets, together with computer simulation, to estimate missing relative potency values across the desired range. Bayesian Markov Chain Monte Carlo modeling is used to generate the distributions of the missing potency levels. Results from use of the reduced procedure are compared to results calculated from a full dataset in Monte Carlo simulation and in a motivating example.

  • Bioassay
  • Validation
  • Bayesian
  • © PDA, Inc. 2018
View Full Text

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 72 (3)
PDA Journal of Pharmaceutical Science and Technology
Vol. 72, Issue 3
May/June 2018
  • Table of Contents
  • Index by Author
Print
Download PDF
Article Alerts
Email Article
Citation Tools
Share
A Novel Method for Qualification of a Potency Assay through Partial Computer Simulation
Steven Novick, Perceval Sondag, Tim Schofield, Kenneth Miller
PDA Journal of Pharmaceutical Science and Technology May 2018, 72 (3) 249-263; DOI: 10.5731/pdajpst.2017.008094
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget

Jump to section

  • Article
    • Abstract
    • 1. Introduction
    • 2. Calculation of Rp for Potency Assay
    • 3. Data Generation for Potency Assay
    • 4. Generating the “Missing” Rp Values
    • 5. Simulation
    • 6. A Motivating Example Data Set
    • 7. Discussion
    • Conflict of Interest Declaration
    • Acknowledgements
    • Reference
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Quantitative and Qualitative Evaluation of Microorganism Profile Identified in Bioburden Analysis in a Biopharmaceutical Facility in Brazil: Criteria for Classification and Management of Results
  • Evaluation of Extreme Depyrogenation Conditions on the Surface Hydrolytic Resistance of Glass Containers for Pharmaceutical Use
  • A Holistic Approach for Filling Volume Variability Evaluation and Control with Statistical Tool
Show more Research

Similar Articles

Keywords

  • Bioassay
  • Validation
  • Bayesian

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A Novel Method for Qualification of a Potency Assay through Partial Computer Simulation
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
1 + 3 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
A Novel Method for Qualification of a Potency Assay through Partial Computer Simulation
Steven Novick, Perceval Sondag, Tim Schofield, Kenneth Miller
PDA Journal of Pharmaceutical Science and Technology May 2018, 72 (3) 249-263; DOI: 10.5731/pdajpst.2017.008094

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.