Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleTECHNOLOGY/APPLICATIONS

Accuracy of Automated Instruments Used in the Pharmaceutical Industry for Integrity Testing Sterilizing Filters

Peter Czermak and Gerardo Catapano
PDA Journal of Pharmaceutical Science and Technology July 2003, 57 (4) 277-286;
Peter Czermak
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: peter.czermak@tg.fh-giessen.de
Gerardo Catapano
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

In the pharmaceutical industry, the integrity of sterile filters is critical to ensure sterility of filtered products. Filter integrity is frequently tested by measuring gas diffusion across water-contacting hydrophobic or hydrophilic membranes with the same automated test devices. Constant device accuracy over the whole range of possible operating conditions is an especially important requirement, as set by the GMP regulations for product critical devices.

In this paper, we investigate the accuracy of gas diffusion rate and water intrusion rate estimates provided by a batch-operated and a refilling, continuous-flow commercial automated test device used both for diffusive flow tests and water intrusion tests. Tests were performed on custom-designed model filter systems and full-scale filters over a broad range of gas diffusive flow rates and upstream gas volumes. Neither tested device provided accurate measurements of gas diffusion rate when a small gas diffusion flow was measured out of a very large upstream volume. The batch-operated device provided measurements of gas diffusion rates (either gas diffusion or water intrusion rate) with an accuracy that strongly depends on the gas diffusion rate and on the gas volume upstream from the membrane. Gas diffusion rate measurements were particularly biased in diffusive flow tests of filters with less than 500 mL gas upstream volume. Gas diffusion rates were underestimated by as much as −14.5% in diffusive flow tests and −25 % in water intrusion tests. The refilling, continuous flow device generally provided consistent and accurate gas diffusion rate and water intrusion rate measurements within less than 5% of the reference value, practically independent of the gas diffusion flow rate and upstream volume value. A serious bias was only noted in diffusion flow tests at very high upstream volumes and low gas diffusion rate. The results reported in this paper show the importance of qualifying the automated test devices used to assess sterile filter integrity.

  • Accuracy
  • Diffusive Flow Test
  • Sterile Filter
  • Validation
  • Water Intrusion Test

Footnotes

  • Copyright © Parenteral Drug Association. All rights reserved.

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology
Vol. 57, Issue 4
July/August 2003
  • Table of Contents
  • Index by Author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Accuracy of Automated Instruments Used in the Pharmaceutical Industry for Integrity Testing Sterilizing Filters
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
3 + 6 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Accuracy of Automated Instruments Used in the Pharmaceutical Industry for Integrity Testing Sterilizing Filters
Peter Czermak, Gerardo Catapano
PDA Journal of Pharmaceutical Science and Technology Jul 2003, 57 (4) 277-286;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Accuracy of Automated Instruments Used in the Pharmaceutical Industry for Integrity Testing Sterilizing Filters
Peter Czermak, Gerardo Catapano
PDA Journal of Pharmaceutical Science and Technology Jul 2003, 57 (4) 277-286;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Evaluation of Steam Sterilization Processes: Comparing Calculations Using Temperature Data and Biointegrator Reduction Data and Calculation of Theoretical Temperature Difference
  • Optimization of the Drug Solution Preparation Process for a Production-Scale Crossflow Ultrafiltration System
  • Bacterial Adhesion: Considerations Within A Risk-Based Approach To Cleaning Validation
Show more Technology/Applications

Similar Articles

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire