Abstract
A programme of work has been initiated to further the understanding of the impact of the environment surrounding a Blow/Fill/Seal (BFS) machine upon the microbiological quality of processed product. A dedicated facility (Challenge Room) has been constructed and qualified to provide for the production and containment of dispersions of micro organisms in air of a room housing an operating BFS machine of a given style and configuration. The facility achieves homogeneous distribution of generated dispersions throughout the Challenge Room air, including that within and close to the critical area in which aseptic BFS operations occur. Generated microbial dispersions can be maintained in the room over extended time periods (up to 600 min) at a desired concentration within the range 101 to 107 cfu m−3. They can also be produced employing different cell types, including bacterial endospores, Gram-positive and Gram-negative vegetative cells and yeast cells. Effective containment of dispersions is achieved while ‘cards of product’ (vials in sets) are conveyed from the Challenge Room to an adjacent Packing and Storage Area. Decontamination of the room and the housed BFS machine is accomplished through exposure to chlorine dioxide gas at a concentration of 1.0 mg dm−3 for 120 min at room temperature (∼23 °C).
- Blow/Fill/Seal
- BFS
- microbial dispersions
- containment
- microbial challenges
- chlorine dioxide decontamination
Footnotes
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.