Abstract
This paper describes the assessment of the BioVigilant® IMD-A™, a novel optical spectroscopy technology for the detection, sizing, and quantification of both viable and nonviable particles in real time. A comparative-study of a prototype design with conventional air sampling systems (the MAS-100™ and the CLiMET CI-450t) is presented. Studies have demonstrated that the BioVigilant IMD-A is capable of simultaneously and instantaneously enumerating both viable and nonviable particles in a variety of classified and uncontrolled environments. In general, the data for the IMD-A and the CLiMET followed a similar trend of increasing counts for both the ≥0.5 μm and the ≥5.0 μm nonviable particles when sampling progressed from the most controlled area (Grade A) to the least controlled area (a loading dock open to the outside of the facility). Zero viable particle counts were observed for both the IMD-A and the MAS when sampling the Grade A location. However, there was a trend for the IMD-A to detect significantly greater numbers of viable particles when monitoring all other sampling locations, especially those locations representing the least controlled environments. In addition, the IMD-A also detected, sized, and enumerated both viable and nonviable particles in a continuous sampling mode. The IMD-A technology's ability to provide real-time data may offer the industry an unprecedented advantage over growth-based bioaerosol samplers for monitoring the state of microbiological control in pharmaceutical manufacturing environments.
Footnotes
- © PDA, Inc. 2009
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.