Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleResearch

A Vial Container Closure System Performance Optimization Case Study Using Comprehensive Dimensional Stack-Up Analyses

Anthony Bucci, Le Ho, Lauren Orme and Qingyu Zeng
PDA Journal of Pharmaceutical Science and Technology July 2020, 74 (4) 368-376; DOI: https://doi.org/10.5731/pdajpst.2019.010843
Anthony Bucci
West Pharmaceutical Services, Inc.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Le Ho
West Pharmaceutical Services, Inc.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lauren Orme
West Pharmaceutical Services, Inc.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Qingyu Zeng
West Pharmaceutical Services, Inc.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: qingyu.zeng@westpharma.com
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Compatible vial container closure system (CCS) components in combination with a proper capping process are crucial to ensuring reliable performance, maintaining container closure integrity (CCI), and achieving CCS visual acceptance. CCI is essential for parenteral packaging and must be maintained throughout the entire sealed drug product life. In order to build the most robust CCS performance, many variables, including component selection, fit, function, and capping processes, must be set according to the actual dimensions of the CCS components used. However, conventional CCS stack-up calculations are based on dimensional engineering data and its tolerance from CCS component drawings without consideration of the real statistical distributions and their resultant impact on the risk of CCS end performance. CCS dimensional variations may lead to capping failure, resulting in CCS visual defects, CCI failure, and potentially costly destruction of an entire CCS production batch. In this paper, we demonstrated a comprehensive approach utilizing real CCS component dimensional data as a statistical input for CCS dimension stack-up calculations to calculate the actual CCS end performance window and the CCS's quantitative failure risk to determine the CCS's optimal sealing performance and visual acceptance under different stopper compression percentages. We examined two vial CCSs differing by the stopper as a case study. Each component was measured and included in comprehensive dimensional stack-up calculations. The resulting statistical distributions were used to examine component variability and stack-up assemblies at multiple stopper compressions and to identify the optimal CCS based on the performance window generated from the real data. Using this data-driven approach, we quantitatively identified that as little as 5% stopper compression difference could impact the CCS chosen. More importantly, comprehensive dimensional stack-up calculations can assist in selecting the best vial CCS and appropriate stopper compression, as well as troubleshoot processing concerns and ensure operation within the optimal CCS performance window.

  • Container closure system (CCS)
  • Residual seal force (RSF)
  • Container closure integrity (CCI)
  • Stopper
  • Vial
  • Cap
  • Seal
  • Capping
  • Modeling
  • Performance Window
  • Dimensional Testing
  • © PDA, Inc. 2020
View Full Text

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 74 (4)
PDA Journal of Pharmaceutical Science and Technology
Vol. 74, Issue 4
July/August 2020
  • Table of Contents
  • Index by Author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A Vial Container Closure System Performance Optimization Case Study Using Comprehensive Dimensional Stack-Up Analyses
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
13 + 4 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
A Vial Container Closure System Performance Optimization Case Study Using Comprehensive Dimensional Stack-Up Analyses
Anthony Bucci, Le Ho, Lauren Orme, Qingyu Zeng
PDA Journal of Pharmaceutical Science and Technology Jul 2020, 74 (4) 368-376; DOI: 10.5731/pdajpst.2019.010843

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
A Vial Container Closure System Performance Optimization Case Study Using Comprehensive Dimensional Stack-Up Analyses
Anthony Bucci, Le Ho, Lauren Orme, Qingyu Zeng
PDA Journal of Pharmaceutical Science and Technology Jul 2020, 74 (4) 368-376; DOI: 10.5731/pdajpst.2019.010843
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Experimental Testing Setup
    • Experimental Testing, Results, and Discussion
    • Conclusion
    • Conflict of Interest Declaration
    • Acknowledgments
    • References
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Quantitative and Qualitative Evaluation of Microorganism Profile Identified in Bioburden Analysis in a Biopharmaceutical Facility in Brazil: Criteria for Classification and Management of Results
  • Evaluation of Extreme Depyrogenation Conditions on the Surface Hydrolytic Resistance of Glass Containers for Pharmaceutical Use
  • A Holistic Approach for Filling Volume Variability Evaluation and Control with Statistical Tool
Show more Research

Similar Articles

Keywords

  • Container closure system (CCS)
  • Residual seal force (RSF)
  • Container closure integrity (CCI)
  • Stopper
  • Vial
  • Cap
  • Seal
  • Capping
  • Modeling
  • Performance Window
  • Dimensional Testing

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire