Abstract
The sterile barrier is one of the most important aspects of the container closure integrity (CCI) for a prefilled syringe (PFS or syringe). This crucial barrier enables the protection of the syringe contents from contamination. The plunger stopper (stopper) is naturally in a stationary position that is controlled by the static friction between the plunger stopper and the syringe barrel wall. When an applied force is greater than the static friction, which is commonly known as the break-loose force, the plunger stopper will move. In such conditions, the stopper movement can further be increased if an air bubble (AB) is introduced between the liquid fill in the syringe and the stopper during the stoppering process. This additional movement can occur when the pressure differential between the gaseous headspace inside the syringe and the external atmosphere is large enough that the force exerted on the stopper exceeds the break-loose force of the syringe. This can occur during altitude or temperature changes incurred during aerial or mountainous transport. This article, therefore, discusses the relationship between stopper movement and initial headspace (air bubble size/ABS) in a 2.25 mL Type I glass syringe using theoretical and empirical approaches. The results showed the maximum initial headspace needed to enable CCI at specified altitudes and plunger stopper movements for the syringe-plunger stopper combination used in the study. Empirical data also indicated that CCI can be maintained for this syringe-plunger stopper combination with up to 9.0 mm initial headspace at altitudes up to 17,000 feet.
- © PDA, Inc. 2023
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.