Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleTechnology/Application

Comparative Leachable Study of Glass Vials to Demonstrate the Impact of Low Fill Volume

Bernhard Hladik, Florence Buscke, Robert Frost and Uwe Rothhaar
PDA Journal of Pharmaceutical Science and Technology July 2019, 73 (4) 345-355; DOI: https://doi.org/10.5731/pdajpst.2018.009472
Bernhard Hladik
1SCHOTT Pharmaceutical Systems, SCHOTT AG, Hattenbergstrasse 10, 55122 Mainz, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: bernhard.hladik@schott.com
Florence Buscke
1SCHOTT Pharmaceutical Systems, SCHOTT AG, Hattenbergstrasse 10, 55122 Mainz, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Robert Frost
1SCHOTT Pharmaceutical Systems, SCHOTT AG, Hattenbergstrasse 10, 55122 Mainz, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Uwe Rothhaar
2SCHOTT Pharma Services, SCHOTT AG, Hattenbergstrasse 10, 55122 Mainz, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

The pharmacopeia method for measuring the chemical durability of parenteral glass packaging is the hydrolytic resistance test in which the vial is filled to 90% of its brimful volume as described, for example, in USP <660>. However, an increasing number of innovative drugs are filled significantly below the nominal volume of the vial. As a consequence, the determined hydrolytic resistance is not representative of the concentrations of leached “glass” elements for low fill volumes. This is attributable to two main factors: Firstly, an increasing ratio of the wetted surface to volume and secondly an increased leaching tendency typically observed with borosilicate glass of the wall near bottom area, especially when standard manufacturing technology is applied.

The extent of both contributing effects has been analyzed by determining the amounts of the representative leached “glass” elements, boron, sodium, and silicon, after vial storage for 24 weeks at 40°C with different fill volumes (0.5, 1.0, and 2.0 mL). The vials which have been investigated in this study have a nominal fill volume of 2 mL, were made from Type I class B borosilicate glass (Fiolax®) and from aluminosilicate glass and were filled with either purified water or a 15% KCl solution.

The standard conversion process for tubing into vials was used for Fiolax vials (standard quality vials) and for aluminosilicate vials. In addition, an optimized conversion process (delamination controlled technology) was used to create low-fill quality Fiolax vials. The vial quality obtained from the two different converting technologies greatly influenced the concentrations of leached “glass” elements measured, especially when low fill volumes were used.

LAY ABSTRACT: Borosilicate glass containers, because of their chemical inertness, excellent barrier properties, high transparency, and mechanical stability, have been successfully used for decades to package parenteral drug formulations. Nevertheless, Type I glass can be altered over a period of time when in contact with the drug formulation. The result of this interaction is even more pronounced for some new innovative drugs that are delivered to the patient in small dosages significantly below the nominal storage capacity of the glass vials. When the fill volume of the vials is reduced, the contribution of the bottom area to the wetted surface increases, resulting in a higher surface-to-volume ratio. Therefore, the concentrations of leached elements will be increased and this can cause problems for sensitive medical products. This effect is not usually observed with the standard test procedures described in the pharmacopeia because the vials are filled with a high volume to 90% brimful capacity (e.g., as described in USP <660>). In this study, the leachable behaviors of vials made of borosilicate and aluminosilicate glass were evaluated by using medium and low fill volumes with storage for 24 weeks at 40°C. The standard conversion process to manufacture a vial from glass tubing introduces volatile “glass” elements into the vial wall near the bottom area. This mechanism has been described and supported by time-of-flight secondary ion mass spectrometry (TOF-SIMS) measurements of the inner vial surface as reported by Rupertus et al. The diffusion mechanism of volatile components will increase the leaching propensity of the vial, especially for low fill volumes. However, innovative manufacturing techniques are able to avoid the diffusion of volatile elements into the wall near the bottom area. This is achieved by a specific process setup in combination with a suitable monitoring test during vial production, which gives a quantitative measure of the leaching tendency of the wall near the bottom area. Borosilicate glass vials manufactured with this setup (low-fill quality vials) showed a drastic reduction in leachables, especially with low fill volumes. Vials composed of a boron-free glass showed no advantages in terms of leaching behavior when compared with borosilicate glass vials in general.

  • Low fill volume, Glass dissolution
  • pH shift
  • Leachables
  • Aluminosilicate
  • Quicktest
  • © PDA, Inc. 2019
View Full Text

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 73 (4)
PDA Journal of Pharmaceutical Science and Technology
Vol. 73, Issue 4
July/August 2019
  • Table of Contents
  • Index by Author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comparative Leachable Study of Glass Vials to Demonstrate the Impact of Low Fill Volume
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
8 + 3 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Comparative Leachable Study of Glass Vials to Demonstrate the Impact of Low Fill Volume
Bernhard Hladik, Florence Buscke, Robert Frost, Uwe Rothhaar
PDA Journal of Pharmaceutical Science and Technology Jul 2019, 73 (4) 345-355; DOI: 10.5731/pdajpst.2018.009472

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comparative Leachable Study of Glass Vials to Demonstrate the Impact of Low Fill Volume
Bernhard Hladik, Florence Buscke, Robert Frost, Uwe Rothhaar
PDA Journal of Pharmaceutical Science and Technology Jul 2019, 73 (4) 345-355; DOI: 10.5731/pdajpst.2018.009472
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Materials and Methods
    • Results and Discussion
    • Conclusion
    • Conflict of Interest Declaration
    • References
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • A Predictive Modeling Approach to Support the Overfill Volume Definition of Liquid-in-Vial Drug Products
  • Materials in Manufacturing and Packaging Systems as Sources of Elemental Impurities in Packaged Drug Products: An Updated Literature Review
  • Google Scholar

More in this TOC Section

  • Mechanical Container Closure Integrity Test: A Method for Cartridge Systems
  • A Container Closure Integrity Test Method for Vials Stored at Cryogenic Conditions Using Headspace Oxygen Analysis
  • Best Practices for Microbial Challenge In-Use Studies to Evaluate the Microbial Growth Potential of Parenteral Biological Products; Industry and Regulatory Considerations
Show more Technology/Application

Similar Articles

Keywords

  • Low fill volume, Glass dissolution
  • pH shift
  • Leachables
  • Aluminosilicate
  • Quicktest

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire