Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleTechnology/Application

Charting and Evaluation of Real-Time Continuous Monitoring Water Bioburden

Raphael Bar
PDA Journal of Pharmaceutical Science and Technology September 2019, 73 (5) 496-509; DOI: https://doi.org/10.5731/pdajpst.2018.009837
Raphael Bar
BR Consulting, Ness Ziona, Israel 7403774
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

References

  1. 1.↵
    U.S. Food and Drug Administration, Guidance for Industry: PAT—A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance. Center for Veterinary Medicine, Center for Drug Evaluation and Research: Rockville, MD, 2004.
  2. 2.↵
    Technical Report No. 33 (Revised): Evaluation, Validation and Implementation of Alternative Rapid Microbiological Methods; Parenteral Drug Association Inc., 2013.
  3. 3.↵
    1. McIver D.
    Using RMM for Environmental Monitoring Rapid Microbiological Methods Can Also Be Used for Air and Surface Monitoring, with Modest Regulatory Resistance. Pharma Manufacturing [Online] 2010, August 16. https://www.pharmamanufacturing.com/articles/2010/115/?show=al,l (accessed Dec 29, 2018).
  4. 4.↵
    1. Riley B.
    Rapid Microbiology Methods in the Pharmaceutical Industry. Am. Pharm. Rev. [Online] 2006, February 1. https://www.americanpharmaceuticalreview.com/Featured-Articles/113094-Rapid-Microbiology-Methods-in-the-Pharmaceutical-Industry/ (accessed Dec 29, 2018).
  5. 5.↵
    1. Miller M. J.
    The Regulatory Acceptance of Rapid Microbiological Methods. Eur. Pharm. Rev. [Online] 2017, 22 (3), 55–58. https://www.europeanpharmaceuticalreview.com/article/62880/rapid-microbiological-methods-regulatory-acceptance/ (accessed Dec 29, 2018).
    OpenUrl
  6. 6.↵
    1. Denoya C.
    Real Time Continuous Microbiological Monitoring. BioPharm Int. [Online] 2016, 29 (10), 38–40. http://www.biopharminternational.com/print/320548?page=full (accessed Dec 29, 2018).
    OpenUrl
  7. 7.↵
    1. Anders H. J.,
    2. Ayers F.,
    3. Fitch B.,
    4. Forng R. Y.,
    5. Hooper S.,
    6. Luebke M.,
    7. Mateffy J.,
    8. Noverini P.,
    9. Termine B.,
    10. Yan L.,
    11. Weber J.
    Practical Application of Online Water Bioburden Analyzers in Pharmaceutical Manufacturing. Pharmaceutical Online [Online] 2017, July 24. https://www.pharmaceuticalonline.com/doc/practical-application-of-online-water-bioburden-analyzers-in-pharmaceutical-manufacturing (accessed Dec 30, 2018).
  8. 8.↵
    1. Bar R.
    Charting and Evaluation of Environmental Microbial Monitoring Data. PDA J. Pharm. Sci. Technol. 2015, 69 (6), 743–761.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Runger G. C.,
    2. Willemain T. R.
    Model-Based and Model-Free Control of Autocorrelated Processes. J. Qual. Technol. 1995, 27 (4), 283–292.
    OpenUrl
  10. 10.↵
    1. Montgomery D. C.
    Introduction to Statistical Process Control; 4th ed.; John Wiley & Sons: New York, 2001; pp 460–468.
  11. 11.↵
    1. Woodall W. H.,
    2. Faltin F. W.
    Autocorrelated Data and SPC. ASQC Statistics Division Newsletter 1993, 13 (4), 18–21.
    OpenUrl
  12. 12.↵
    1. Madsen R. E.,
    2. Moldenhauer J.
    1. Bar R.
    Approaches to Charting and Setting Control Limits for Environmental Monitoring Microbial Data. In PDA/DHI Contamination Control in Healthcare Product Manufacturing; Madsen R. E., Moldenhauer J., Eds.; Davis Healthcare International Publishing: River Grove, IL, 2016; Vol. 4, Chapter 10, pp 277–310.
    OpenUrl
  13. 13.↵
    1. Alwan L. C.,
    2. Roberts H. V.
    Time Series Modeling for Statistical Process Control. J. Bus. Econ. Stat. 1988, 6 (1), 87–95.
    OpenUrlCrossRef
  14. 14.↵
    1. Wheeler D. J.
    Advanced Topics in Statistical Process Control, 2nd ed.; SPC Press: Knoxville, TN, 2004; Chapter 12.
  15. 15.↵
    1. Wheeler D. J.
    How to Handle High-Volume Data Streams. Presented at the Nestlé Process Analytical Technology Network Meeting [Online] 2017. www.spcpress.com/pdf/DJW311.pdf (accessed Dec 30, 2018).
  16. 16.↵
    U.S. Pharmacopeial Convention. General Chapter <1231> Water for Pharmaceutical Purposes. In USP 41–NF 36; USP: Rockville, MD.
  17. 17.↵
    1. Cundell T.
    Microbial Monitoring of Pharmaceutical Grade Water Systems – Common Misconceptions. Am. Pharm. Rev. [Online] 2018, Oct. 11. https://www.americanpharmaceuticalreview.com/Featured-Articles/354483-Microbial-Monitoring-of-Pharmaceutical-Grade-Water-Systems-Common-Misconceptions/ (accessed March 23, 2019).
  18. 18.↵
    1. Wheeler D. J.
    Working with Rare Events: What Happens When the Average Count Gets Very Small? Quality Digest [Online] 2011, Oct 28. https://www.qualitydigest.com/inside/quality-insider-article/working-rare-events.html (accessed March 23, 2019).
  19. 19.↵
    1. Ball C.,
    2. Gampfer J.,
    3. Grunkemeier J.,
    4. Roche M.,
    5. Laenan L.,
    6. Baker D.,
    7. O’Neill R. B. J.,
    8. Germansderfer A.,
    9. Fleming J.,
    10. McNay J.
    Continued Process Verification: An Industry Position Paper with Example Plan [Online]; BioPhorum Operations Group, 2014; Chapter 12. http://www.biophorum.com/cpv-case-study (accessed Dec 30, 2018).
  20. 20.↵
    Minitab Inc. Variables Control Charts http://support.minitab.com/en-us/minitab/18/Assistant_Variables_Control_Charts.pdf (accessed Dec. 30, 2018).
  21. 21.↵
    1. Shewhart W.
    Economic Control of Quality of Manufactured Product American Society for Quality Control, ASQC Quality Press: Milwaukee, WI, 1980, p 6.
PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 73 (5)
PDA Journal of Pharmaceutical Science and Technology
Vol. 73, Issue 5
September/October 2019
  • Table of Contents
  • Index by Author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Charting and Evaluation of Real-Time Continuous Monitoring Water Bioburden
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
12 + 5 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Charting and Evaluation of Real-Time Continuous Monitoring Water Bioburden
Raphael Bar
PDA Journal of Pharmaceutical Science and Technology Sep 2019, 73 (5) 496-509; DOI: 10.5731/pdajpst.2018.009837

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Charting and Evaluation of Real-Time Continuous Monitoring Water Bioburden
Raphael Bar
PDA Journal of Pharmaceutical Science and Technology Sep 2019, 73 (5) 496-509; DOI: 10.5731/pdajpst.2018.009837
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Conclusion
    • Conflict of Interest Declaration
    • Acknowledgments
    • References
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Mechanical Container Closure Integrity Test: A Method for Cartridge Systems
  • A Container Closure Integrity Test Method for Vials Stored at Cryogenic Conditions Using Headspace Oxygen Analysis
  • Best Practices for Microbial Challenge In-Use Studies to Evaluate the Microbial Growth Potential of Parenteral Biological Products; Industry and Regulatory Considerations
Show more Technology/Application

Similar Articles

Keywords

  • Water bioburden
  • Rapid microbiological method
  • Real-time continuous monitoring
  • laser-induced fluorescence
  • Statistical process control (SPC)
  • Autocorrelation
  • Time series
  • ARIMA model
  • Rational sampling
  • Batch means control charts
  • Control charts of individual values
  • Setting control limits

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire