Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
Research ArticleResearch

Correlating GC/MS Relative Response Factors to Analyte’s Physicochemical and Chromatographic Properties to Facilitate the Quantitation of Organic Extractables and Leachables in Non-Targeted Analysis (NTA). Concepts and Empirical Considerations

Dennis Jenke, Piet Christiaens, Philippe Verlinde, Jan Baeten and Jean-Marie Beusen
PDA Journal of Pharmaceutical Science and Technology November 2024, 78 (6) 625-642; DOI: https://doi.org/10.5731/pdajpst.2023.012884
Dennis Jenke
Nelson Labs, Romeinsestraat 12, 3001 Heverlee, Belgium
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: dennisjenke@triadscientificsolutions.com
Piet Christiaens
Nelson Labs, Romeinsestraat 12, 3001 Heverlee, Belgium
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Philippe Verlinde
Nelson Labs, Romeinsestraat 12, 3001 Heverlee, Belgium
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jan Baeten
Nelson Labs, Romeinsestraat 12, 3001 Heverlee, Belgium
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jean-Marie Beusen
Nelson Labs, Romeinsestraat 12, 3001 Heverlee, Belgium
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Leachables in drug products and from medical devices can adversely affect patient health and thus must be identified and quantified. Accurate and protective quantitation in target analysis for leachables (and extractables as potential leachables) is accomplished via compound-specific calibration curves. Quantification in non-targeted analysis (NTA) is complicated by the variable relative response factors (RRFs) among and between individual leachables and the circumstance that the leachables are not known until the NTA is completed. Protective quantitation in NTA is accomplished in various ways, depending on the identification status of the analyte. When an analyte’s identity is confirmed, it is quantified using the compound’s own RRF, obtained by analysis of a reference standard. In other identification circumstances, the concentration is calculated using a surrogate response, either linked to a surrogate compound or representative of a domain of leachables. Given the difficulty in matching an analyte with a proper surrogate, this article addresses quantitation via the latter approach. This article uses a database of >3000 GC/MS response factors to empirically divide the population of leachables into response factor domains, differentiated by either the analyte’s polarity (log Po/w) or retention time. Using the database, mean RRF values and uncertainty factors (UFs) are established for each domain and are used for quantitation. Protective quantitation is accomplished for nearly 84% of all leachables in the database (and presumably the entire population) by placing an analyte into its proper domain and then using the mean RRF divided by the UF for that domain as a universal response factor for all compounds in the domain.

  • Extractables
  • Leachables
  • Quantitation
  • Non-target analysis
  • Relative response factor
  • Uncertainty factor
  • © PDA, Inc. 2024
View Full Text

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 78 (6)
PDA Journal of Pharmaceutical Science and Technology
Vol. 78, Issue 6
November/December 2024
  • Table of Contents
  • Index by Author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Correlating GC/MS Relative Response Factors to Analyte’s Physicochemical and Chromatographic Properties to Facilitate the Quantitation of Organic Extractables and Leachables in Non-Targeted Analysis (NTA). Concepts and Empirical Considerations
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
13 + 4 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Correlating GC/MS Relative Response Factors to Analyte’s Physicochemical and Chromatographic Properties to Facilitate the Quantitation of Organic Extractables and Leachables in Non-Targeted Analysis (NTA). Concepts and Empirical Considerations
Dennis Jenke, Piet Christiaens, Philippe Verlinde, Jan Baeten, Jean-Marie Beusen
PDA Journal of Pharmaceutical Science and Technology Nov 2024, 78 (6) 625-642; DOI: 10.5731/pdajpst.2023.012884

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Correlating GC/MS Relative Response Factors to Analyte’s Physicochemical and Chromatographic Properties to Facilitate the Quantitation of Organic Extractables and Leachables in Non-Targeted Analysis (NTA). Concepts and Empirical Considerations
Dennis Jenke, Piet Christiaens, Philippe Verlinde, Jan Baeten, Jean-Marie Beusen
PDA Journal of Pharmaceutical Science and Technology Nov 2024, 78 (6) 625-642; DOI: 10.5731/pdajpst.2023.012884
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Experimental
    • Results
    • Discussion
    • Conclusions
    • Conflict of Interest Declaration
    • References
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Quantitative and Qualitative Evaluation of Microorganism Profile Identified in Bioburden Analysis in a Biopharmaceutical Facility in Brazil: Criteria for Classification and Management of Results
  • Evaluation of Extreme Depyrogenation Conditions on the Surface Hydrolytic Resistance of Glass Containers for Pharmaceutical Use
  • A Holistic Approach for Filling Volume Variability Evaluation and Control with Statistical Tool
Show more Research

Similar Articles

Keywords

  • Extractables
  • Leachables
  • Quantitation
  • Non-target analysis
  • Relative response factor
  • Uncertainty Factor

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire